Learn what RoHS compliant painting means, which coating ingredients cause failures, how coatings are tested to IEC 62321, and what paperwork to request from a supplier.
RoHS compliant painting means the paint, primer and pretreatment on an electrical or electronic part contain none of the restricted substances above their limits. Those limits are 0.1% for lead, mercury and hexavalent chromium, and 0.01% for cadmium. Confirm it with IEC 62321 test results and supplier paperwork.
Which coatings does RoHS cover?
RoHS restricts ten substances: lead, cadmium, mercury, hexavalent chromium, PBB, PBDE, and four phthalates (DEHP, BBP, DBP and DIBP). Paint is covered because the rules apply to the whole product, and the coating is part of it.
Use this rule to decide whether a coated part falls under RoHS:
- Is it electrical or electronic equipment, or a cable, spare part or component of it? Since 22 July 2019 the scope is open, so nearly all such equipment is covered. Medical devices and monitoring and control instruments came under it earlier, between 2014 and 2017.
- Is it excluded? Exclusions include military equipment, space equipment and large-scale stationary industrial tools.
- Does it end up on the European market, or does your customer sell into Europe? If so, you may still have to comply, because components are often affected even when the rules target finished products.
If the part is equipment or a component of it, is not excluded, and ends up on the European market, you need a parts finisher that can document its coating system.
We paint homes, commercial buildings and industrial facilities, and we don't offer certified finishing of electronic parts. If the coating is on a warehouse floor, structural steel or equipment rather than the product itself, RoHS does not apply and our commercial and industrial painting team can quote it. For general building work, see types, costs and what to check when hiring a painter, and how industrial protective coatings work for floors and steel.
Which coating ingredients fail RoHS, and what replaces them?
The usual culprits are hex chrome in corrosion-inhibiting primers and pretreatments, lead and cadmium in pigments, brominated flame retardants in plastics, and phthalate plasticisers.
| Substance | Where it hides in a coating system |
|---|---|
| Lead | Pigments, driers |
| Cadmium | Pigments |
| Mercury | Additives, rare in coatings |
| Hexavalent chromium | Corrosion-inhibiting primers, conversion pretreatments |
| PBB and PBDE | Flame retardants in plastic housings |
| Phthalates | Plasticisers in coatings and plastics |
Hex chrome inhibits corrosion, which is why it was everywhere. It is also a carcinogen. The real substitutes are chromate-free primers, such as a metalized, sacrificial aluminum-rich primer, and Cr(VI)-free pretreatments. For the other substances, the fix is to specify pigments, additives, flame retardants and plasticisers that don't contain them.
How is a coating tested for RoHS compliance?
Labs measure the restricted substances using the methods in IEC 62321. That standard covers lead, mercury, cadmium, hexavalent chromium, PBB and PBDE. Ask separately how the four phthalates were checked.
The limits apply to each homogeneous material, meaning each coating layer on its own. In parts per million, 0.1% is 1,000 ppm and 0.01% is 100 ppm. Cadmium's limit is ten times tighter, so a cadmium pigment is the easiest way for a coating to fail.
What paperwork should you get from a coating supplier?
Ask for test results to IEC 62321 and a written statement that the full coating system meets the RoHS limits. Both feed the technical documentation RoHS 2 requires before a product goes on the European market.
Make sure the statement names the pretreatment, primer and topcoat, not just one layer. Keep the paperwork with each batch or part number so you can trace it later. If you need a building, floor or piece of plant equipment coated instead, contact PaintPro for an estimate.